Intake-exhaust balance, the basic rule
Attic ventilation depends on continuous air movement: cold air enters at the soffits low on the slope and exits at the ridge. You need roughly as much intake area as exhaust, distributed along the full length.
Adding exhaust without sufficient intake doesn't ventilate more: the system ends up pulling warm air from the house through the ceiling, which worsens exactly the problem you meant to fix.
Ice dams, symptom rather than cause
When house heat warms the attic, snow melts on the slope and water runs to the cold overhang, where it refreezes. Ice builds and water eventually backs up under the shingles.
Replacing the roof fixes nothing: the cause is thermal, not mechanical. You have to seal ceiling air leaks, bring insulation back to depth and restore airflow. It costs less than a roof and solves the problem permanently.
Blocked soffits, the most widespread defect
Blowing insulation into an attic without installing baffles blocks the soffit intakes. The attic ends up with exhaust and no supply. It's extremely common after a well-intentioned energy upgrade.
We check soffit clearance as a matter of course before proposing anything else. Installing baffles and clearing the intakes costs little and resolves a good share of cases.
Powered attic fans
An electric roof fan looks like an obvious solution, but in a poorly sealed house it pulls heated humid air from the living space through the ceiling. It then raises the heating bill and carries moisture into the attic.
We favour well-balanced passive ventilation, which consumes nothing and doesn't depressurize the house. A powered fan is justified in specific configurations, and only after the ceiling has been sealed.